Euh, i just might have found the something interesting..
This morning, i wanted to check my mails ( which run in a domU ). I noticed i 
couldn't get to it, "Unable to connect", as usual.. But i had cacti open, which 
could read snmp from the server just fine.
I logged in through SSH, and noticed that the date was set to "Fri Dec 22 
22:49:54 CET 2226", and not going forward anymore. The clock had stopped. 

In the meantime, /var/log/messages was spewing messages like this:

[134918.952935] clocksource/0: Time went backwards: delta=-6917269600674797899 
shadow=134918109266738 offset=843667158
[134923.954592] printk: 1157408 messages suppressed.
[134923.954606] clocksource/0: Time went backwards: delta=-6917269595673126078 
shadow=134923109294656 offset=845310074
[134928.952308] printk: 1154382 messages suppressed.
[134928.952323] clocksource/0: Time went backwards: delta=-6917269590675409336 
shadow=134928109321066 offset=842999953

I decided to change something to see if it works, so i did:
cat /sys/devices/system/clocksource/clocksource0/current_clocksource, which 
showed "xen" as usual.
I then did 
echo "jiffies" > 
/sys/devices/system/clocksource/clocksource0/current_clocksource, which 
instantly made my clock run again, and stalled programs revived. I saw my 
webmail ( which was still hanging all the time ) spring to life, along with my 
previously entered reboot command..

Does this narrow down the search to the solution?

Kind regards,

Bart

-- 
"Time went backwards" + freeze for domU's with kernel 2.6.22-xen
https://bugs.launchpad.net/bugs/146924
You received this bug notification because you are a member of Ubuntu
Bugs, which is the bug contact for Ubuntu.

-- 
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to