apport information
** Tags added: apport-collected staging
** Description changed:
x470-I ROG strix motherboard and Ryzen 2700
After
sudo sensors-detect
and answering yes to all the probes the net result is:
"Sorry, no sensors were detected.
Either your system has no sensors, or they are not supported, or
they are connected to an I2C or SMBus adapter that is not
supported."
sensors output lists:
asus-isa-0000
Adapter: ISA adapter
cpu_fan: 0 RPM
nouveau-pci-0900
Adapter: PCI adapter
fan1: 0 RPM
temp1: +65.0°C (high = +95.0°C, hyst = +3.0°C)
(crit = +105.0°C, hyst = +5.0°C)
(emerg = +135.0°C, hyst = +5.0°C)
k10temp-pci-00c3
Adapter: PCI adapter
temp1: +94.2°C (high = +70.0°C)
Where the cpu fan is patently wrong and the k10temp likewise. The
nouveau-pci-0900 appears to be the actual CPU temperature.
May be related to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1740736
Other info:
Description: Ubuntu 18.04 LTS
Release: 18.04
version log:
Ubuntu 4.15.0-22.24-generic 4.15.17
+ ---
+ ApportVersion: 2.20.9-0ubuntu7.1
+ Architecture: amd64
+ AudioDevicesInUse:
+ USER PID ACCESS COMMAND
+ /dev/snd/controlC0: chrisandvera 1765 F.... pulseaudio
+ /dev/snd/controlC1: chrisandvera 1765 F.... pulseaudio
+ CurrentDesktop: GNOME-Flashback:GNOME
+ DistroRelease: Ubuntu 18.04
+ InstallationDate: Installed on 2018-06-01 (0 days ago)
+ InstallationMedia: Ubuntu 18.04 LTS "Bionic Beaver" - Release amd64 (20180426)
+ MachineType: System manufacturer System Product Name
+ Package: linux (not installed)
+ ProcEnviron:
+ TERM=xterm-256color
+ PATH=(custom, no user)
+ XDG_RUNTIME_DIR=<set>
+ LANG=en_CA.UTF-8
+ SHELL=/bin/bash
+ ProcFB: 0 nouveaufb
+ ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-4.15.0-22-generic
root=UUID=ce726f17-d5df-45f7-b3f0-983e883493e6 ro quiet splash vt.handoff=1
+ ProcVersionSignature: Ubuntu 4.15.0-22.24-generic 4.15.17
+ RelatedPackageVersions:
+ linux-restricted-modules-4.15.0-22-generic N/A
+ linux-backports-modules-4.15.0-22-generic N/A
+ linux-firmware 1.173.1
+ StagingDrivers: r8822be
+ Tags: bionic staging
+ Uname: Linux 4.15.0-22-generic x86_64
+ UpgradeStatus: No upgrade log present (probably fresh install)
+ UserGroups: adm cdrom dip lpadmin plugdev sambashare sudo
+ _MarkForUpload: True
+ dmi.bios.date: 04/19/2018
+ dmi.bios.vendor: American Megatrends Inc.
+ dmi.bios.version: 0601
+ dmi.board.asset.tag: Default string
+ dmi.board.name: ROG STRIX X470-I GAMING
+ dmi.board.vendor: ASUSTeK COMPUTER INC.
+ dmi.board.version: Rev 1.xx
+ dmi.chassis.asset.tag: Default string
+ dmi.chassis.type: 3
+ dmi.chassis.vendor: Default string
+ dmi.chassis.version: Default string
+ dmi.modalias:
dmi:bvnAmericanMegatrendsInc.:bvr0601:bd04/19/2018:svnSystemmanufacturer:pnSystemProductName:pvrSystemVersion:rvnASUSTeKCOMPUTERINC.:rnROGSTRIXX470-IGAMING:rvrRev1.xx:cvnDefaultstring:ct3:cvrDefaultstring:
+ dmi.product.family: To be filled by O.E.M.
+ dmi.product.name: System Product Name
+ dmi.product.version: System Version
+ dmi.sys.vendor: System manufacturer
** Attachment added: "AlsaInfo.txt"
https://bugs.launchpad.net/bugs/1774817/+attachment/5147999/+files/AlsaInfo.txt
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1774817
Title:
Temperature sensors on x470 not reporting correctly
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1774817/+subscriptions
--
ubuntu-bugs mailing list
[email protected]