Ryan,

I did some more testing and seems the issue originates from how I do
storage preparation, using the vendor's proprietary tool, during
commissioning I reconfigure all the RAID controllers, during which the
drives get disconnected and re-plugged later. This results that curtin
does not see the bcache drives as attached, but the physical layout on
the drives remain.

I assume curtin only does the wipefs when the bcache devices are attached, 
correct?
What I did for now, maybe just a workaround, but to wipe the drives during the 
drive configuration commission script.

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1778704

Title:
  redeployment of node with bcache fails

To manage notifications about this bug go to:
https://bugs.launchpad.net/curtin/+bug/1778704/+subscriptions

-- 