This bug was fixed in the package ceph - 12.2.12-0ubuntu0.18.04.3
---------------
ceph (12.2.12-0ubuntu0.18.04.3) bionic; urgency=medium
[ James Page ]
* d/p/ceph-volume-wait-for-lvs.patch: Cherry pick inflight fix to
ensure that required wal and db devices are present before
activating OSD's (LP: #1828617).
[ Jesse Williamson ]
* d/p/civetweb-755-1.8-somaxconn-configurable*.patch: Backport changes
to civetweb to allow tuning of SOMAXCONN in Ceph RADOS Gateway
deployments (LP: #1838109).
[ James Page ]
* d/p/rgw-gc-use-aio.patch: Cherry pick fix to switch to using AIO for
garbage collection of objects in the Ceph RADOS Gateway
(LP: #1838858).
[ Eric Desrochers ]
* Ensure that daemons are not automatically restarted during package
upgrades (LP: #1840347):
- d/rules: Use "--no-restart-after-upgrade" and "--no-stop-on-upgrade"
instead of "--no-restart-on-upgrade".
- d/rules: Drop exclusion for ceph-[osd,mon,mds] for restarts.
-- James Page <[email protected]> Fri, 30 Aug 2019 10:11:09 +0100
** Changed in: ceph (Ubuntu Bionic)
Status: Fix Committed => Fix Released
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1838109
Title:
civetweb does not allow tuning of maximum socket connections
To manage notifications about this bug go to:
https://bugs.launchpad.net/ceph/+bug/1838109/+subscriptions
--
ubuntu-bugs mailing list
[email protected]