I add similar communication with "Creality Ender 3" board, just for reference.
So it looks like CR-100 sends answer for M114 command in two lines and that is 
problem for pronterface.

SENT: M105
RECV: ok T:-15.00 /0.00 B:-15.00 /0.00 @:0 B@:0
SENT: M105
RECV: ok T:-15.00 /0.00 B:-15.00 /0.00 @:0 B@:0
SENT: G91
SENT: G0 X10.0 F3000
SENT: G90
SENT: M114
RECV: ok
RECV: ok
RECV: ok
RECV: X:20.00 Y:0.00 Z:2.00 E:0.00 Count X:1600 Y:0 Z:1200
RECV: ok
SENT: M105
RECV: ok T:-15.00 /0.00 B:-15.00 /0.00 @:0 B@:0
SENT: M105
RECV: ok T:-15.00 /0.00 B:-15.00 /0.00 @:0 B@:0

>>> M115
SENDING:M115
FIRMWARE_NAME:Marlin bugfix-1.1.x (Github) 
SOURCE_CODE_URL:https://github.com/MarlinFirmware/Marlin PROTOCOL_VERSION:1.0 
MACHINE_TYPE:Ender-3 EXTRUDER_COUNT:1 UUID:cede2a2f-41a2-4748-9b12-c55c62f367ff
Cap:SERIAL_XON_XOFF:0
Cap:EEPROM:1

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1873691

Title:
  Printrun cannot communicate with Creality CR-100

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/printrun/+bug/1873691/+subscriptions

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to