Public bug reported:
While working on pacemaker, i discovered a issue with timeouts
haproxy_stop_0 on primary 'OCF_TIMEOUT' (198): call=583, status='Timed
Out', exitreason='', last-rc-change='1970-01-04 17:21:18 -05:00',
queued=44ms, exec=176272ms
this lead me down the path of finding that setting a timeout unit value
was not doing anything
primitive haproxy systemd:haproxy \
op monitor interval=2s \
op start interval=0s timeout=500s \
op stop interval=0s timeout=500s \
meta migration-threshold=2
primitive haproxy systemd:haproxy \
op monitor interval=2s \
op start interval=0s timeout=500 \
op stop interval=0s timeout=500 \
meta migration-threshold=2
the two above configs result in the same behaviour, pacemaker/crm seems to be
ignoring the "s"
I file a bug with pacemaker itself
https://bugs.clusterlabs.org/show_bug.cgi?id=5429
but this lead to the following responsed, copied from the ticket:
<<Looking back on your irc chat, I see you have a version of Pacemaker
with a known bug:
<<haproxy_stop_0 on primary 'OCF_TIMEOUT' (198): call=583, status='Timed
Out', exitreason='', last-rc-<<change='1970-01-04 17:21:18 -05:00',
queued=44ms, exec=176272ms
<<The incorrect date is a result of bugs that occur in systemd resources
when Pacemaker 2.0.3 is built <<with the -UPCMK_TIME_EMERGENCY_CGT C
flag (which is not the default). I was only aware of that being the
<<case in one Fedora release. If those are stock Ubuntu packages, please
file an Ubuntu bug to make sure <<they are aware of it.
<<The underlying bugs are fixed as of the Pacemaker 2.0.4 release. If
anyone wants to backport specific <<commits instead, the github pull
requests #1992 and #1997 should take care of it.
It appears the the root cause of my issue with setting timeout values
with units ("600s") is a bug in the build process of ubuntu pacemaker
1) lsb_release -d Description: Ubuntu 20.04 LTS
2) ii pacemaker 2.0.3-3ubuntu3
amd64 cluster resource manager
3) setting "100s" in the timeout of a resource should result in a 100 second
timeout, not a 100 milisecond timeout
4) the settings unit value "s", is being ignored. force me to set the timeout
to 10000 to get a 10 second timeout
** Affects: pacemaker (Ubuntu)
Importance: Undecided
Status: New
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1881762
Title:
resource timeout not respecting units
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/pacemaker/+bug/1881762/+subscriptions
--
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs