** Description changed:
[Impact]
+ Connect the 4K@60Hz monitor on WD19, the monitor can't light.
[Fix]
+ As per DP spec, at first check DP_EXTENDED_RECEIVER_CAP_FIELD_PRESENT.
+ If DP_EXTENDED_RECEIVER_CAP_FIELD_PRESENT is 1, read the DP_DP13_DPCD_REV to
get the faster capability. If DP_EXTENDED_RECEIVER_CAP_FIELD_PRESENT is 0, read
DP_DPCD_REV.
[Test]
+ With the patches, connect 4K@60Hz monitor on WD19, the machine can output the
video to the monitor and the monitor can light.
[Regression]
+ low, Just get one more DPCD from the extended register, compare them and get
the faster one.
** Summary changed:
- Get the right configuration according to the related field of dpcd
+ Get the extended DPCD according to the related field in the DPCD registers.
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1893752
Title:
Get the extended DPCD according to the related field in the DPCD
registers.
To manage notifications about this bug go to:
https://bugs.launchpad.net/hwe-next/+bug/1893752/+subscriptions
--
ubuntu-bugs mailing list
[email protected]