Public bug reported:
After the SRU of LP: #1894323, it looks like a bad behavior in pacemaker
Bionic was exposed:
When declaring the fence_aws primitive, you can either declare it as a
single resource and describe the pcmk_host_map... OR you can declare one
fence resource PER NODE doing the exact same thing BUT using the
"plug/port" resource argument. The thing is... in Focal, both methods
work but in Bionic, the second method does not work.
It is not a big deal as there are some fence agents designed to work
with "pcmk_host_map" only, and some others are designed to work with
"plug/port" argument.
Test case (BIONIC):
Using the fence-agents version from LP: #1894323 you first configure the
fence_aws primitive as:
```
node 1: bionic01
node 2: bionic02
node 3: bionic03
primitive fence-bionic stonith:fence_aws \
params \
access_key="xxxx" \
secret_key="yyyy" \
region="us-east-1" \
pcmk_host_map="bionic01:i-068e134;bionic02:i-0136edd;bionic03:i-0de279ab"
```
and
```
property cib-bootstrap-options: \
have-watchdog=false \
dc-version=1.1.18-2b07d5c5a9 \
cluster-infrastructure=corosync \
stonith-enabled=on \
stonith-action=reboot \
no-quorum-policy=stop \
cluster-name=bionic
```
You can cause an issue in the interconnect and observe the fence_aws
agent working properly. Then, stop the resource and remove it. Configure
the fencing agent as 1 fence resource per node:
```
primitive fence-bionic01 stonith:fence_aws \
params \
access_key="xxxx" \
secret_key="yyyy" \
region="us-east-1" \
pcmk_host_map="bionic01:i-068e134;bionic02:i-0136edd;bionic03:i-0de279ab" \
plug="bionic01:i-068e134de1beddc7f"
primitive fence-bionic02 stonith:fence_aws \
params \
access_key="xxxx" \
secret_key="yyyy" \
region="us-east-1" \
pcmk_host_map="bionic01:i-068e134;bionic02:i-0136edd;bionic03:i-0de279ab" \
plug="bionic02:i-0136eddd045ceb7e2"
primitive fence-bionic03 stonith:fence_aws \
params \
access_key="xxxx" \
secret_key="yyyy" \
region="us-east-1" \
pcmk_host_map="bionic01:i-068e134;bionic02:i-0136edd;bionic03:i-0de279ab" \
plug="bionic03:i-0de279ab4e6d642c8"
location l-fence-bionic01 fence-bionic01 -inf: bionic01
location l-fence-bionic02 fence-bionic02 -inf: bionic02
location l-fence-bionic03 fence-bionic03 -inf: bionic03
```
This last example, using multiple fence resources, works in Focal but
does not work in Bionic (after making sure both had the exact same
fence_aws script version in bug LP: #1894323).
I think a bisection of pacemaker between Bionic and Focal (yes, its bad
because its a major version change) might be needed here to understand
why using "plug" does not work in Bionic.
Looks like Red Hat also faces the same issue at:
https://access.redhat.com/solutions/4642491
Note: I have exhaustively tested the "pcmk_host_map" only primitive and
it worked fine (fencing the correct nodes all the times I fenced the
cluster). Using plug "" in Bionic is not advised as fence_aws fences
other nodes (than the one provided in plug argument).
** Affects: pacemaker (Ubuntu)
Importance: Medium
Status: Confirmed
** Changed in: pacemaker (Ubuntu)
Status: New => Confirmed
** Changed in: pacemaker (Ubuntu)
Importance: Undecided => Medium
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1900374
Title:
fence_aws in Focal and Bionic (LP: #1894323) don't behave the same.
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/pacemaker/+bug/1900374/+subscriptions
--
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs