Public bug reported:

[Summary]
When the monitor ONLY is connected to the WD19 (DP port) and WD19 is connected 
to the type c port than boot the machine, the monitor shows no video output 
after loaded i915.

[Reproduce Steps]
1. connect power cable of WD19
2. connect DP cable from monitor to WD19
3. connect power cable to target system.
4. connect type c cable from WD19 to target system
5. boot up

[Results]
Expected: video output as there is only one monitor connected.
Actual: No video output.

ProblemType: Bug
DistroRelease: Ubuntu 20.04
Package: linux-image-5.6.0-1033-oem 5.6.0-1033.35
ProcVersionSignature: Ubuntu 5.6.0-1033.35-oem 5.6.19
Uname: Linux 5.6.0-1033-oem x86_64
ApportVersion: 2.20.11-0ubuntu27.11
Architecture: amd64
CasperMD5CheckResult: skip
Date: Thu Nov 12 05:11:11 2020
DistributionChannelDescriptor:
 # This is the distribution channel descriptor for the OEM CDs
 # For more information see http://wiki.ubuntu.com/DistributionChannelDescriptor
 canonical-oem-somerville-focal-amd64-20200502-85+fossa-metapod+X40
InstallationDate: Installed on 2020-11-03 (9 days ago)
InstallationMedia: Ubuntu 20.04 "Focal" - Build amd64 LIVE Binary 20200502-05:58
SourcePackage: linux-signed-oem-5.6
UpgradeStatus: No upgrade log present (probably fresh install)

** Affects: hwe-next
     Importance: Undecided
         Status: New

** Affects: linux (Ubuntu)
     Importance: Undecided
         Status: New


** Tags: amd64 apport-bug focal oem-priority originate-from-1901008 somerville

** Tags added: oem-priority originate-from-1901008 somerville

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1903969

Title:
  failed to boot to GUI: i915 0000:00:02.0: [drm] *ERROR* Link Training
  Unsuccessful

To manage notifications about this bug go to:
https://bugs.launchpad.net/hwe-next/+bug/1903969/+subscriptions

-- 
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to