Public bug reported:
[ Impact ]
* Dell would like to disable thermal management on its platform
OptiPlex XE4 on focal
* The reason is that the thermald on focal is too old to support the thermal
policy configured in the BIOS
, it leads the problem in lp:2064083. However, the platform can still rely on
EC to do the thermal management, so that it can omit the issue.
[ Test Plan ]
* Install the package on the target OptiPlex XE4 platform, product sku
0ACB
* Run $ systemctl status thermald
* The status should be inactive
* Run $ systemctl status thermald on other platforms, the status should
be running
[ Where problems could occur ]
* The change only takes place on specified platform, the other
platforms should work as what it was.
[ Other Info ]
* The thermald version after jammy can support the table inside BIOS
correctly, so there is no need to apply the patch to the codename >= 22.04.
** Affects: oem-priority
Importance: Undecided
Status: New
** Affects: thermald (Ubuntu)
Importance: Undecided
Status: New
** Tags: oem-priority originate-from-2065137 somerville
** Tags added: oem-priority originate-from-2065137 somerville
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2068546
Title:
Exclude thermald thermal management for Dell Optiplex XE4
To manage notifications about this bug go to:
https://bugs.launchpad.net/oem-priority/+bug/2068546/+subscriptions
--
ubuntu-bugs mailing list
[email protected]