This bug was fixed in the package mutter - 47.0-1ubuntu4
---------------
mutter (47.0-1ubuntu4) oracular; urgency=high
* Add a missing break in derive_logical_monitor_size as part of
x11-Add-support-for-fractional-scaling-using-Randr.patch.
Because falling through two switch cases was causing the scale to be
applied twice, which then resulted in mode verification failing later.
(LP: #2080374)
-- Daniel van Vugt <[email protected]> Mon, 30 Sep 2024
18:15:25 +0800
** Changed in: mutter (Ubuntu)
Status: In Progress => Fix Released
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2080374
Title:
Unable to change display settings ("Changes Cannot be Applied", "This
could be due to hardware limitations")
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/gnome-control-center/+bug/2080374/+subscriptions
--