Public bug reported:

[ Impact ]

 * On Dell SD25TB4 dock

 * Try to get the device information by $ fwupdmgr get-devices

 * Try to unplug the dock and plug it back again

 * The firmware info is not listed by $ fwupdmgr get-devices

[ Test Plan ]

 * On Dell machine which supports TBT4

 * Connect to Dell SD25TB4 that utilizes dell-kestrel plugin

 * run command "fwupdmgr get-devices" can see the RMM firmware info

 * unplug the Dock and plug it back

 * run command "fwupdmgr get-devices" can still get the correct firmware
info


[ Where problems could occur ]

 * The SRU requires the version bump to 1.9.30 by leveraging the exception 
document
   https://wiki.ubuntu.com/firmware-updates

[ Additional information ]

 * The upstream fix for the issue,
https://github.com/fwupd/fwupd/pull/8630

** Affects: fwupd (Ubuntu)
     Importance: Undecided
         Status: New

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2110209