Public bug reported:
As detected by the ovn system testsuite the following test fails when
upgrading iprotue2 from 6.14 to more recent versions:
egress qos
The command being executed by the testsuite is:
tc class show dev ovs-public
And the printed value becomes:
class htb 1:2 parent 1:fffe prio 0 rate 12Kbit ceil 34359Mbit burst
375000b cburst 374933b
While the expected output is:
class htb 1:2 parent 1:fffe prio 0 rate 12Kbit ceil 34359Mbit burst
375000b cburst 373662b
The issue appears to be present in iproute2 versions 6.17.0-1,
6.16.0-1ubuntu2
Downgrading to 6.14.0-1ubuntu1 makes the problem go away.
** Affects: iproute2 (Ubuntu)
Importance: Undecided
Status: New
** Affects: ovn (Ubuntu)
Importance: Undecided
Status: New
** Tags: update-excuse
** Package changed: openvswitch (Ubuntu) => iproute2 (Ubuntu)
** Also affects: ovn (Ubuntu)
Importance: Undecided
Status: New
** Tags added: update-excuse
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2129005
Title:
tc class show dev provides incorrect value for cburst
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/iproute2/+bug/2129005/+subscriptions
--
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs