Hello,

I tried to replicate this problem on an amd64 VM with 4 SCSI multipath devices.
That said I was able to:

* Install the OS on mpatha, complete the installation, come back to installer
* Install the OS on mpathb, complete the installation, come back to installer
* Install the OS on mpathc, complete the installation, come back to installer
* Install the OS on mpathd, complete the installation, come back to installer

All 4 OSes have been installed using the ubuntu-25.10-live-server-
amd64.iso installer. Logs down below.

I suppose there is a timing aspect that is different when using HBAs &
LUNs.

mpatha (0QEMU_QEMU_HARDDISK_MPIO0) dm-0 QEMU,QEMU HARDDISK
size=12G features='0' hwhandler='0' wp=rw
|-+- policy='service-time 0' prio=1 status=active
| `- 0:0:0:0 sda 8:0  active ready running
`-+- policy='service-time 0' prio=1 status=enabled
  `- 0:0:1:0 sdb 8:16 active ready running
mpathb (0QEMU_QEMU_HARDDISK_MPIO1) dm-1 QEMU,QEMU HARDDISK
size=12G features='0' hwhandler='0' wp=rw
|-+- policy='service-time 0' prio=1 status=active
| `- 0:0:3:0 sdd 8:48 active ready running
`-+- policy='service-time 0' prio=1 status=enabled
  `- 0:0:2:0 sdc 8:32 active ready running
mpathc (0QEMU_QEMU_HARDDISK_MPIO2) dm-2 QEMU,QEMU HARDDISK
size=12G features='0' hwhandler='0' wp=rw
|-+- policy='service-time 0' prio=1 status=active
| `- 0:0:5:0 sdf 8:80 active ready running
`-+- policy='service-time 0' prio=1 status=enabled
  `- 0:0:4:0 sde 8:64 active ready running
mpathd (0QEMU_QEMU_HARDDISK_MPIO3) dm-3 QEMU,QEMU HARDDISK
size=12G features='0' hwhandler='0' wp=rw
|-+- policy='service-time 0' prio=1 status=active
| `- 0:0:6:0 sdg 8:96  active ready running
`-+- policy='service-time 0' prio=1 status=enabled
  `- 0:0:7:0 sdh 8:112 active ready running

Jan 16 13:52:32 ubuntu-server multipathd[1718]: multipathd v0.11.1: start up
Jan 16 13:52:32 ubuntu-server multipathd[1718]: reconfigure: setting up paths 
and maps
Jan 16 13:52:32 ubuntu-server multipathd[1718]: _check_bindings_file: failed to 
read header from /etc/multipath/bindings
Jan 16 13:52:32 ubuntu-server multipathd[1718]: updated bindings file 
/etc/multipath/bindings
Jan 16 13:52:32 ubuntu-server multipathd[1718]: updated bindings file 
/etc/multipath/bindings
Jan 16 13:52:32 ubuntu-server multipathd[1718]: sda: setting scsi timeouts is 
unsupported for protocol scsi:unspec
Jan 16 13:52:32 ubuntu-server multipathd[1718]: sdb: setting scsi timeouts is 
unsupported for protocol scsi:unspec
Jan 16 13:52:32 ubuntu-server multipathd[1718]: 0QEMU_QEMU_HARDDISK_MPIO0: 
rename 0QEMU_QEMU_HARDDISK_MPIO0 to mpatha
Jan 16 13:52:32 ubuntu-server multipathd[1718]: updated bindings file 
/etc/multipath/bindings
Jan 16 13:52:32 ubuntu-server multipathd[1718]: sdc: setting scsi timeouts is 
unsupported for protocol scsi:unspec
Jan 16 13:52:32 ubuntu-server multipathd[1718]: sdd: setting scsi timeouts is 
unsupported for protocol scsi:unspec
Jan 16 13:52:32 ubuntu-server multipathd[1718]: 0QEMU_QEMU_HARDDISK_MPIO1: 
rename 0QEMU_QEMU_HARDDISK_MPIO1 to mpathb
Jan 16 13:52:32 ubuntu-server multipathd[1718]: updated bindings file 
/etc/multipath/bindings
Jan 16 13:52:32 ubuntu-server multipathd[1718]: sde: setting scsi timeouts is 
unsupported for protocol scsi:unspec
Jan 16 13:52:32 ubuntu-server multipathd[1718]: sdf: setting scsi timeouts is 
unsupported for protocol scsi:unspec
Jan 16 13:52:32 ubuntu-server multipathd[1718]: 0QEMU_QEMU_HARDDISK_MPIO2: 
rename 0QEMU_QEMU_HARDDISK_MPIO2 to mpathc
Jan 16 13:52:32 ubuntu-server multipathd[1718]: updated bindings file 
/etc/multipath/bindings
Jan 16 13:52:32 ubuntu-server multipathd[1718]: sdg: setting scsi timeouts is 
unsupported for protocol scsi:unspec
Jan 16 13:52:32 ubuntu-server multipathd[1718]: sdh: setting scsi timeouts is 
unsupported for protocol scsi:unspec
Jan 16 13:52:32 ubuntu-server multipathd[1718]: 0QEMU_QEMU_HARDDISK_MPIO3: 
rename 0QEMU_QEMU_HARDDISK_MPIO3 to mpathd

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2133480

Title:
  Ubuntu25.10: Ubuntu host installation is failing while doing
  installation on multiple[2 or more] multipath SAN disks!

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu-power-systems/+bug/2133480/+subscriptions


-- 
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to