Public bug reported:
1) Ubuntu 24.04.4 LTS (Noble Numbat)
2) systemsettings: 4:5.27.11-0ubuntu2
plasma-workspace: 4:5.27.12-0ubuntu0.1
3) System Settings window should display its content (sidebar,
settings modules) normally.
4) The System Settings window renders black. Content is only
briefly visible when moving the mouse inside the window.
This appears to be a version mismatch: plasma-workspace was
updated to 5.27.12 via noble-updates but systemsettings
remained at 5.27.11 from noble/universe.
XCB errors in journal:
kwin_core: XCB error: 152 (BadDamage), sequence: 1002,
resource id: 27263000, major code: 143 (DAMAGE), minor code: 3
GPU: NVIDIA RTX 4000 Ada Generation Laptop GPU
Driver: 595.58.03
Session: X11
ProblemType: Bug
DistroRelease: Ubuntu 24.04
Package: systemsettings 4:5.27.11-0ubuntu2
ProcVersionSignature: Ubuntu 6.17.0-23.23~24.04.1-generic 6.17.13
Uname: Linux 6.17.0-23-generic x86_64
ApportVersion: 2.28.1-0ubuntu3.8
Architecture: amd64
CasperMD5CheckResult: pass
CurrentDesktop: KDE
Date: Wed May 13 17:08:54 2026
InstallationDate: Installed on 2025-06-06 (341 days ago)
InstallationMedia: Ubuntu 24.04.2 LTS "Noble Numbat" - Release amd64 (20250215)
SourcePackage: systemsettings
UpgradeStatus: No upgrade log present (probably fresh install)
** Affects: systemsettings (Ubuntu)
Importance: Undecided
Status: New
** Tags: amd64 apport-bug noble
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2152565
Title:
systemsettings window renders black - version mismatch with plasma-
workspace (5.27.11 vs 5.27.12)
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/systemsettings/+bug/2152565/+subscriptions
--
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs