================================== 108/154 ===================================
test: libfprint:drivers / egis_etu905
start time: 15:27:57
duration: 0.40s
result: exit status 1
command: MESON_BUILD_ROOT=/<<PKGBUILDDIR>>/obj-x86_64-linux-gnu
G_TEST_SRCDIR=/<<PKGBUILDDIR>>/tests
GI_TYPELIB_PATH=/<<PKGBUILDDIR>>/obj-x86_64-linux-gnu/libfprint
G_TEST_BUILDDIR=/<<PKGBUILDDIR>>/obj-x86_64-linux-gnu/tests MALLOC_PERTURB_=201
FP_DEVICE_EMULATION=1 FP_PRINTS_PATH=/<<PKGBUILDDIR>>/examples/prints
NO_AT_BRIDGE=1 FP_DRIVERS_ALLOWLIST=egis_etu905
MESON_SOURCE_ROOT=/<<PKGBUILDDIR>>
UBSAN_OPTIONS=halt_on_error=1:abort_on_error=1:print_summary=1:print_stacktrace=1
G_DEBUG=fatal-warnings
ASAN_OPTIONS=halt_on_error=1:abort_on_error=1:print_summary=1
LD_LIBRARY_PATH=/<<PKGBUILDDIR>>/obj-x86_64-linux-gnu/libfprint
G_MESSAGES_DEBUG=all /usr/bin/python3 /<<PKGBUILDDIR>>/tests/umockdev-test.py
/<<PKGBUILDDIR>>/tests/egis_etu905
----------------------------------- stdout -----------------------------------
** (umockdev-run:9310): DEBUG: 15:27:57.704: umockdev.vala:127: Created udev
test bed /tmp/umockdev.NH4MP3
** (umockdev-run:9310): DEBUG: 15:27:57.705: umockdev.vala:1307: parsing device
description for /devices/pci0000:00/0000:00:08.1/0000:05:00.4/usb3/3-3
** (umockdev-run:9310): DEBUG: 15:27:57.713: umockdev.vala:1385: creating
device /devices/pci0000:00/0000:00:08.1/0000:05:00.4/usb3/3-3 (subsystem usb)
** (umockdev-run:9310): DEBUG: 15:27:57.718: umockdev.vala:1431:
create_node_for_device: creating file device
/tmp/umockdev.NH4MP3/dev/bus/usb/003/002
** (umockdev-run:9310): DEBUG: 15:27:57.719: umockdev.vala:1307: parsing device
description for /devices/pci0000:00/0000:00:08.1/0000:05:00.4/usb3
** (umockdev-run:9310): DEBUG: 15:27:57.725: umockdev.vala:1385: creating
device /devices/pci0000:00/0000:00:08.1/0000:05:00.4/usb3 (subsystem usb)
** (umockdev-run:9310): DEBUG: 15:27:57.730: umockdev.vala:1431:
create_node_for_device: creating file device
/tmp/umockdev.NH4MP3/dev/bus/usb/003/001
** (umockdev-run:9310): DEBUG: 15:27:57.730: umockdev.vala:1307: parsing device
description for /devices/pci0000:00/0000:00:08.1/0000:05:00.4
** (umockdev-run:9310): DEBUG: 15:27:57.734: umockdev.vala:1385: creating
device /devices/pci0000:00/0000:00:08.1/0000:05:00.4 (subsystem pci)
** (umockdev-run:9310): DEBUG: 15:27:57.740: umockdev.vala:1307: parsing device
description for /devices/pci0000:00/0000:00:08.1
** (umockdev-run:9310): DEBUG: 15:27:57.741: umockdev.vala:1385: creating
device /devices/pci0000:00/0000:00:08.1 (subsystem pci)
(process:9314): libfprint-context-DEBUG: 15:27:57.811: Initializing FpContext
(libfprint version 1.94.7+tod1)
(process:9314): libfprint-tod-DEBUG: 15:27:57.811: Impossible to load the
shared drivers dir Error opening directory
“/usr/lib/x86_64-linux-gnu/libfprint-2/tod-1”: No such file or directory
(process:9314): libfprint-egis_etu905-DEBUG: 15:27:57.814: 246378499:
../libfprint/drivers/egismoc/egis_etu905.c:1593
(process:9314): libfprint-context-DEBUG: 15:27:57.814: No driver found for USB
device 1D6B:0002
(process:9314): libfprint-egis_etu905-DEBUG: 15:27:57.815: egis_etu905_probe
enter -->
(process:9314): libfprint-device-DEBUG: 15:27:57.821: Device reported probe
completion
(process:9314): libfprint-device-DEBUG: 15:27:57.821: Completing action
FPI_DEVICE_ACTION_PROBE in idle!
(process:9314): libfprint-device-DEBUG: 15:27:57.821: Not updating temperature
model, device can run continuously!
(process:9314): libfprint-egis_etu905-DEBUG: 15:27:57.822: Opening device
(process:9314): libfprint-SSM-DEBUG: 15:27:57.823: [egis_etu905]
DEV_INIT_STATES entering state 0
(process:9314): libfprint-egis_etu905-DEBUG: 15:27:57.823: Execute command and
get response
(process:9314): libfprint-egis_etu905-DEBUG: 15:27:57.823: Get check bytes
(process:9314): libfprint-SSM-DEBUG: 15:27:57.823: [egis_etu905] CMD_STATES
entering state 0
(process:9314): libfprint-SSM-DEBUG: 15:27:57.823: [egis_etu905] CMD_STATES
entering state 1
(process:9314): libfprint-SSM-DEBUG: 15:27:57.824: [egis_etu905] SSM CMD_STATES
failed in state 1 with error: The driver encountered a protocol error with the
device.
(process:9314): libfprint-SSM-DEBUG: 15:27:57.824: [egis_etu905] CMD_STATES
completed with error: The driver encountered a protocol error with the device.
(process:9314): libfprint-egis_etu905-DEBUG: 15:27:57.824: Firmware version
callback
(process:9314): libfprint-SSM-DEBUG: 15:27:57.824: [egis_etu905] SSM
DEV_INIT_STATES failed in state 0 with error: The driver encountered a protocol
error with the device.
(process:9314): libfprint-SSM-DEBUG: 15:27:57.824: [egis_etu905]
DEV_INIT_STATES completed with error: The driver encountered a protocol error
with the device.
(process:9314): libfprint-egis_etu905-DEBUG: 15:27:57.824: Task SSM done
(process:9314): libfprint-device-DEBUG: 15:27:57.824: Device reported generic
error (The driver encountered a protocol error with the device.) during action;
action was: FPI_DEVICE_ACTION_OPEN
(process:9314): libfprint-device-DEBUG: 15:27:57.824: Device reported open
completion
(process:9314): libfprint-device-DEBUG: 15:27:57.824: Completing action
FPI_DEVICE_ACTION_OPEN in idle!
(process:9314): libfprint-device-DEBUG: 15:27:57.824: Not updating temperature
model, device can run continuously!
----------------------------------- stderr -----------------------------------
libusb: error [op_handle_events] cannot find handle for fd 9
...
libusb: error [op_handle_events] cannot find handle for fd 9
libusb: error [op_handle_events] cannot find handle for fd 9
libusb: error [op_handle_events] cannot find handle for fd 9
libusb: error [op_handle_events] cannot find handle for fd 9
Traceback (most recent call last):
File "/<<PKGBUILDDIR>>/tests/egis_etu905/custom.py", line 31, in <module>
d.open_sync()
gi.repository.GLib.GError: fp - device - error - quark: The driver encountered
a protocol error with the device. (5)
** (umockdev-run:9310): WARNING **: 15:27:57.846: umockdev-pcap.vala:90: Error
resolving IOCtl data: Error receiving data: Connection reset by peer
Traceback (most recent call last):
File "/<<PKGBUILDDIR>>/tests/umockdev-test.py", line 124, in <module>
raise e
File "/<<PKGBUILDDIR>>/tests/umockdev-test.py", line 118, in <module>
custom()
File "/<<PKGBUILDDIR>>/tests/umockdev-test.py", line 110, in custom
subprocess.check_call(get_umockdev_runner("custom") +
File "/usr/lib/python3.12/subprocess.py", line 413, in check_call
raise CalledProcessError(retcode, cmd)
subprocess.CalledProcessError: Command '['umockdev-run', '-d',
'/<<PKGBUILDDIR>>/tests/egis_etu905/device', '-p',
'/sys/devices/pci0000:00/0000:00:08.1/0000:05:00.4/usb3/3-3=/<<PKGBUILDDIR>>/tests/egis_etu905/custom.pcapng',
'--', '/usr/bin/python3', '/<<PKGBUILDDIR>>/tests/egis_etu905/custom.py']'
died with <Signals.SIGTRAP: 5>.
==============================================================================
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2148374
Title:
[SRU] Add driver for egis_etu905 fingerprint reader [1c7a:05ae]
To manage notifications about this bug go to:
https://bugs.launchpad.net/oem-priority/+bug/2148374/+subscriptions
--