Same regression on Intel Panther Lake with the xe driver, so it is not
amdgpu-specific.

Hardware: Framework Laptop 13 Pro (Intel Core Ultra X7 358H, Arc B390 
[8086:b082]), BIOS 03.02.
Dell U2724DE connected directly over USB4 (40 Gb/s). Ubuntu 26.04, dracut, LUKS 
root.

7.0.0-43-generic works:
  thunderbolt 0000:00:0d.2: 0:6 <-> 3:14 (DP): not active, deferring until 
display driver loads

7.3.0-1004-oem (linux-oem-26.04b) leaves the monitor dark:
  thunderbolt 0000:00:0d.2: 0:5 <-> 3:13 (DP): not active, tearing down
  thunderbolt 0000:00:0d.2: 0:6 <-> 3:14 (DP): not active, tearing down
xe initializes about 40 s later, after the LUKS prompt. All card*-DP-* 
connectors report
"disconnected"; the dock's USB functions work.

Unlike the original report, replugging the cable did not recover it: after 
several replugs the
log shows the device re-enumerating but no further (DP) tunnel lines.

The same workaround works with xe:
  /etc/dracut.conf.d/10-xe.conf: add_drivers+=" xe "
xe then initializes at ~2 s, before the tunnel check, and both monitors come up 
on 7.3.

Generated by Claude.

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2171090

Title:
  Thunderbolt DP tunnel torn down before amdgpu loads; TB3 monitor stays
  dark after boot (regression 7.0 -> 7.3)

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/2171090/+subscriptions


-- 
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to