Hello!

When you insert your card, there should be 2 ttyS ports on your system,
you can check "dmesg" output for numbers, typycally it will be
/dev/ttyS0 and /dev/ttyS1.

minicom is the best tool to test it, disable all the paryty, hw flow
control. Then shortcut 3 and 4 pins with a jumper, then you'll type and
get the echo back on the screen, that's the best way to test RS-232 and
other one serial links. If it does that's okay. Try both ports couse you
can't be sure which one is ttyS0 so on. By the way argosy card still
works for me on all my systems including ubuntu one, debian and gentoo.
Nobody cares about old/acient/obsolute pcmcia cards but all the way
someone still uses it. Do we have to make it work, or not? What's that
harmradio call?

vitja.

-- 