This bug was fixed in the package ltspfs - 0.5.0~bzr20080109-3ubuntu2

---------------
ltspfs (0.5.0~bzr20080109-3ubuntu2) hardy; urgency=low

  * udev-scripts-security-regression.dpatch (LP: #218231) due to security fixes 
in
    ldm local devices didnt get the right DISPLAY variable to get their
    authentication info for mounting. This patch provides the DISPLAY variable 
in
    the udev scripts and disables X forwarding for the ssh tunnel accordingly.
  * cdrom-naming-regression.dpatch (LP: #218962) in this ltspfs release the cd
    service gets dynamically started from udev instead of running as a daemon.
    This change caused the mountpoint name in /media/$USER/ to become the
    devicename (i.e. dev-scsicd0) instead of the everywhere matched label
    "cdrom". The patch restores the old behavior of always setting the label
    to "cdrom" so the right icon will be applied on the desktop and the places
    menu.

 -- Oliver Grawert <[EMAIL PROTECTED]>   Fri, 18 Apr 2008 01:56:29 +0200

** Changed in: ltspfs (Ubuntu)
       Status: New => Fix Released

-- 
wrong icons for cdroms on ltsp clients
https://bugs.launchpad.net/bugs/218962
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.

-- 
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to