On Tue, May 6, 2014 at 4:50 PM, Kaj Ailomaa <[email protected]> wrote:
> > > On Tue, May 6, 2014, at 05:01 PM, Mac wrote: > > (I think) Previously (AV Linux & UBS 12) the Pulse sink and source was > > there but not connected. > > Then my script connected them where I wanted them to go. The script still > > does this, but > > the pulse output is already connected to the AF12 ch1 & 2 and then my > > script connects them > > to ch1 & 2 again. So I want Pulse source & sink, I just don't want it to > > be > > auto connected. > > > > I'm pretty sure the behavior has been the same all along. Did some > googling, and found that there in deed is an option for stopping the > sink and source from auto-connecting, by adding the option: > connect=false > > http://lists.freedesktop.org/archives/pulseaudio-discuss/2007-July/000420.html > > So, if you want to have the sink and source loaded automatically, but > not auto-connect, change the line in /etc/pulse/default.pa to: > > load-module module-jackdbus-detect channels=2 connect=false > > Modified default.pa as above and it works. I now get 2 pulse sink and 2 pulse source, but nothing connected. Thanks for the help. Mac
-- ubuntu-studio-users mailing list [email protected] Modify settings or unsubscribe at: https://lists.ubuntu.com/mailman/listinfo/ubuntu-studio-users