Hi all, I have the following problem: I' have connected my SCIF1 port (of sh2a 7203) to a MAX485, and the TXEn/!RxEn to an I/O port. I had the idea to write a driver for proc FS to manage the TxEn/!RxEn line and using the ttySCx driver to send and receive data at 38400. But I need to wait the end of the last byte trasmission before to set low the TxEn/!RxEn line. Now I'm doing it with a dilay time; but I was looking for a more elegent solution
Any suggestion for me? Thanks a lot -- Fabio Giovagnini Aurion s.r.l. P.I e C.F. 00885711200 Tel. +39.051.594.78.24 Cell. +39.335.83.50.919 _______________________________________________ uClinux-dev mailing list uClinux-dev@uclinux.org http://mailman.uclinux.org/mailman/listinfo/uclinux-dev This message was resent by uclinux-dev@uclinux.org To unsubscribe see: http://mailman.uclinux.org/mailman/options/uclinux-dev