Hi to all,
I have an issue to the RS232 serial port on a Coldfire board equipped
with uClinux. I have set the serial port with a baudrate of 57600 bps,
it is connected to a third-party device, but it doesn't work (all
charachters are corrupted). If I connect a PC directly to the device
with 57600 bps, it works.
If the bps is put down to 19200, also the connection by the board works.
This is due to the fact that the third party device probably has a
baudrate lightly different from 57600 bps and the PC serail port can
adjust its frequency according to the device one, while Coldfire cannot.
My question is: is there a way to configure the serial port by uClinux
such that also Coldfire can adjust its frequency?
Alternatively, can I configure the serial port with a baudrate slightly
different from the standard ones (for example: 57500 in place of 57600)?
Thank you all!
Regards
--
Salvatore Frizzoli
Software Developer
Research& Development Department
IMS srl
Via Sagittario, 5
Fraz. Pontecchio Marconi
40037 Sasso Marconi (BO)
Italy
Tel. ++39 051 846851
Fax ++39 051 846856
mail: s f r i z z o l i (at) i m s i t a l y (dot) c o m
http://www.imsitaly.com