https://issues.apache.org/jira/browse/UIMA-838?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Marshall Schor reassigned UIMA-838:
-----------------------------------

    Assignee: Marshall Schor

> Incorrect support for process CAS error threshold count and threshold window 
> -----------------------------------------------------------------------------
>
>                 Key: UIMA-838
>                 URL: https://issues.apache.org/jira/browse/UIMA-838
>             Project: UIMA
>          Issue Type: Bug
>          Components: Async Scaleout
>            Reporter: Burn Lewis
>            Assignee: Marshall Schor
>             Fix For: 2.2.2S
>
>         Attachments: UIMA-838-docs.patch, UIMA-838-docs2.patch, 
> UIMA-838-fix2.patch, UIMA-838-test.patch, UIMA-838.patch
>
>
> The thresholdAction should be taken when the number of CAS errors reaches the 
> thresholdCount value within the last thresholdWindow CASes.  A 
> thresholdWindow of 0 means an infinite window, so the action is taken when 
> the total number of errors reaches the thresholdCount.  A thresholdCount of 0 
> means an infinite limit, errors are ignored.  A thresholdCount of 1 means 
> that the first error triggers the action, hence the action must be taken when 
> the threshold is REACHED, not exceeded as stated in the current docs.  
> (Although thresholds usually apply when exceeded, making the thresholdCount 
> be the number permitted would require using a value such as -1 for no 
> threshold, in contrast to our use of 0 to mean no timeout and no window)
> It should be an error to specify a (non-zero) thresholdWindow that is smaller 
> than the thresholdCount ... an impossible situation.
> Note that if thresholdCount = 1 the thresholdWindow value is irrelevant, and 
> if thresholdCount = thresholdWindow the action is taken when that many 
> consecutive errors occur.

-- 
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.

Reply via email to