A CAS multiplier has the ability to create new CASes; one input CAS could be used to create many, or many input CASes used to create one. An input CAS cannot be "swallowed" by a CM; it is considered to be released when the CM returns hasNext()=false.
A flow controller would be the best way to remove a CAS from the flow. If you are using the CPM to construct your processing pipeline, note that it does not support the CM either. Why not use an aggregate to assemble all your components, which would enable use of a flow controller? Eddie On Thu, May 8, 2008 at 8:46 AM, Christoph Büscher < [EMAIL PROTECTED]> wrote: > Hi, > > just a short question concerning the correct use of a CAS Multiplier in > UIMA. As I understand it's usually the job of a CAS Multiplier to split > CASes into multiple parts/segments. Is it also an acceptable behaviour for > such a component to output no CAS at all when certain conditions are met? Or > does the framework complain or will behave strangely if a CAS enters the > Multiplier but never passes it? > I'm trying remove documents that meet a certain condition from the flow > completely. I don't want to use a Flow Controller because I don't have an > Aggregate to add it to. > Thanks, > > -- > -------------------------------- > Christoph Büscher >