Thanks Will,

Yup speed nonegotiate got one end up at least - so we are now half way there.



Sent from my iPhone

On 17 Aug 2013, at 07:56, Will Hargrave <[email protected]> wrote:

>
> On 16 Aug 2013, at 21:48, Ben King <[email protected]> wrote:
>
>> Anyway come the install they deploy SM with LX SFPs, the link between
>> the sites is up the link light is on on their end of the LX link to us
>> but our end won't light - we are terminating into a 6500 SUP720-3B at
>> each end.
>
> Sounds like 1000Base-X autoneg. try toggling 'speed nonegotiate' / 'no speed 
> nonegotiate'
>
>> VM are now trying to argue that it's because it's too close, ie below
>> LX minima link (2m patch lead). However we know their optics light
>> when in our kit and while I know it's a bit short and ultimately it's
>> probably shortening the life of the optics but fundamentally I think
>> it should work.
>
>
> Realistically there is no minimum distance for 1000LX, and you can sit there 
> running with a 2m patch lead until the cows come home. Reference a BT Sinet 
> document maybe? ;-)
>
> --
> Will Hargrave
> +44 114 303 4444
>
>
>
>

Reply via email to