Interestingly I have been seeing similar failures lately, but on other 3rd 
party optics. Not had a failed FS.com optic yet. Typically it has been resolved 
by just reseating the optic.

Oli

-----Original Message-----
From: uknof <[email protected]> On Behalf Of Stuart Henderson
Sent: 09 August 2018 12:34
To: uknof <[email protected]>
Subject: [uknof] fs reliability

I've been trying out FS transceivers. Nothing fancy, just 10Gb LR SFP+ for data 
centre interconnects etc. Out of 8 deployed there have been
2 where the link has failed, then the reported Tx power from DOM has shown as 
-40.0 dBm - one shortly after deploying, one after ~2 months.
Worse still it's intermittent, they have come back to life afterwards.
fs support think this is faulty modules rather than a switch problem.

I wondered if anyone else is seeing a similar failure mode, or what sort of 
failure rate you're seeing? (FS themselves are claiming <1.5% but then they 
would, wouldn't they..)

Should I just buy flexoptix? They are over twice the price though it doesn't 
take many train tickets to London to cover that ..



Reply via email to