Bob, AGM batteries will last longer than flooded wet cell batteries. As far as the state they are in many yards are now switching to conductance meters rather than just a load test as it gives a more precise reading of the batteries ability to be conductive. While a simple voltage test and load test may show ok it will not show if a cell is going bad till it's real bad. Last year I purchased one ( not cheap ) and it has told me batteries that were 11.5 volts were still good so I charged them on a smart charger and they indeed were just in need of a charge. FYI one of my customers has a single 8d AGM that is eight years old and working fine It is however on a gas engine.
-- You received this message because you are subscribed to the Google Groups "UnifliteWorld" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send email to [email protected]. Visit this group at http://groups.google.com/group/unifliteworld?hl=en. For more options, visit https://groups.google.com/groups/opt_out.