*Doug* ... I have a '79 42' Double Cabin Sedan (w. 6-71N's) that only ever 
had 3 tanks .. two 200 USg saddle tanks and a 100USg aft center tank ... 
the aft center tank started leaking with the previous owner so he had it 
removed ... if your aft tanks are sitting in a bilge area that you cannot 
easily access (as mine was), you need to ensure they are not sitting in 
residual bilge water that the pump or pumps cannot scavenge out of there 
... if you don't, and, if your tanks are aluminum, as mine was, you could 
eventually have corrosion-perforated leaking tanks as well ... you also 
need to ensure you are running fresh fuel through them on a regular basis 
(sounds to me like you have been, even if you don't fully understand how) 
... many DCS owners isolated and ignored their aft, center tank for too 
long and I've looked at some boats where the tank is still there and intact 
but full of sludge ... 

Anyways, I've got the same engines as you and I should point out (in case 
you didn't already realize) that those engines are always returning fuel to 
the tanks - based entirely on the shutoff valves configuration (mounted to 
the aft engine room bulkhead on my boat).

I've never heard of this gravity feeding arrangement on a Uniflite that you 
speak of, but of course yours is an entirely different model and obviously 
has more tankage ... my tank source(s) of feed to the engines and generator 
as well as fuel return from all 3 motors is/are controlled entirely by the 
shutoff valves ... I run the Port engine from the Port saddle tank and the 
fuel return is directed back to that same tank, ditto for the Stbd. side 
... with my generator feed line normally shutoff (my boat does not have a 
generator return line shutoff valve), unless I am using the genset of 
course ... however, should I wish to (i.e. trimming), I can transfer fuel 
from one tank/side to the other based soley on the shutoff valves 
configuration.  This capability can quickly become a critical issue if you 
don't understand what's happening - you can overfill one tank if both 
returns are feeding into it while the engines are being supplied by the 
other tank ... sounds far-fetched, however, the previous owner of my boat 
managed to find a way to do just that ... for some unknown reason - I 
assumed a possible bad load of fuel in the isolated tank but that has not 
turned out to be the case.

I believe you need to study your specific owner's manual regarding fuel 
control (if you don't have that, you need to find someone who does have a 
copy - from a model and year as close to your own as possible), find your 
fuel manifolding center (shutoff valves array) and study it at length ... 
until you are dead certain of which lines feed to (larger I.D. copper line) 
and return from (smaller I.D. copper line) each engine and your generator 
... then ... which other shutoff valves can be used to isolate each 
individual tank.  Once you have all that figured out, draw up a logical 
diagram and physically label everything, if that's not been done already 
... I have shutoff valves config. diagrams placarded on my e. r. aft 
bulkhead for each possible fuel control scenario ... in case someone other 
than myself needs to quickly make sense of it in order to make changes 
while underway.

*Kevin Mc*

-- 
You received this message because you are subscribed to the Google Groups 
"UnifliteWorld" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/unifliteworld/fcf9cc59-b282-4fd2-ac31-9c228d0c968b%40googlegroups.com.

Reply via email to