On 4/18/22 18:44, Mahesh Vardhamanaiah wrote:
Hi all,
Need your help regarding an urgent issue where we are observing an issue with
Freebsd stable/12. The data toggles for BOT endpoint
(DATA0/DATA1) are out of sync with respect to EP and the system experiences
the READ(10) errors. The READ(10) error recovers within
couple of retries most of the times but few cases we have observed that the
read retries gets exhausted and system moves to unusable state
(continuous g_vfs_done() errors) . We are using Junos but the xhci driver
etc.. are all pristine stable 12 drivers no Juniper specific changes.
This issue was never observed with Linux kernel 5.4.2 on the same HW suspecting
if it's a xhci driver error recovery issue.
Errors Seen on console
(da0:umass-sim0:0:0:0): READ(10). CDB: 28 00 00 28 cf 28 00 00 40 00
(da0:umass-sim0:0:0:0): CAM status: CCB request completed with an error
(da0:umass-sim0:0:0:0): Retrying command, 3 more tries remain
(da0:umass-sim0:0:0:0): READ(10). CDB: 28 00 00 28 cf 28 00 00 40 00
(da0:umass-sim0:0:0:0): CAM status: CCB request completed with an error
(da0:umass-sim0:0:0:0): Retrying command, 2 more tries remain
FreeBSD/arm (Amnesiac) (ttyu0)
login:
Please let us know is there a place holder to upload the traces and provide a
link here ?
Thanks,
Mahesh
Hi Mahesh,
Do you have wire recording using Ellisys or the Beagle, showing which
side is at fault of the data toggle error?
Is this issue reproducible using the EHCI HC driver?
Is the device connected at USB 3.x or USB 2.0 speed?
--HPS