Hi 像你描述的,单盘对单任务还存在 IO 瓶颈,这里是单 container 吗?像前面大家说的,你需要确认这么大的 IO 访问是符合预期的,如果符合预期的话,你可以尝试增加 blockcache 和 memtable 的大小,将更多的数据放到内存。
另外,你使用的是什么 state 类型,valuestate 和 liststate 的话,能否换成 mapstate 来处理。同时,你可以看下 rocksdb 的 log,看看是否有什么可以优化的地方 Best, Congxian Biao Liu <[email protected]> 于2019年9月23日周一 下午2:39写道: > Hello, > > IO 量这么大符合预期吗?而且是读硬盘打满。 > 有没有尝试过调优? > 1. 业务方面的调优,例如对 state 的使用是否合理 > 2. 系统层面的调优,例如 incremental checkpoint [1] > > 1. > > https://ci.apache.org/projects/flink/flink-docs-release-1.9/dev/stream/state/checkpointing.html#state-backend-incremental > > Thanks, > Biao /'bɪ.aʊ/ > > > > On Tue, 10 Sep 2019 at 14:39, Wesley Peng <[email protected]> wrote: > > > > > > > on 2019/9/10 13:47, 蒋涛涛 wrote: > > > 尝试手段: > > > > > > 1. 手动迁移IO比较高的任务到其他机器,但是yarn任务提交比较随机,只能偶尔为之 > > > > > > 2. 目前没有SSD,只能用普通STATA盘,目前加了两块盘提示磁盘IO能力,但是单盘对单任务的磁盘IO瓶颈还在 > > > > > > 还有哪些策略可以解决或者缓解么? > > > > It seems the tricks to improve RocksDB's throughput might be helpfu. > > > > With writes and reads accessing mostly the recent data, our goal is to > > let them stay in memory as much as possible without using up all the > > memory on the server. The following parameters are worth tuning: > > > > Block cache size: When uncompressed blocks are read from SSTables, they > > are cached in memory. The amount of data that can be stored before > > eviction policies apply is determined by the block cache size. The > > bigger the better. > > > > Write buffer size: How big can Memtable get before it is frozen. > > Generally, the bigger the better. The tradeoff is that big write buffer > > takes more memory and longer to flush to disk and to recover. > > > > Write buffer number: How many Memtables to keep before flushing to > > SSTable. Generally, the bigger the better. Similarly, the tradeoff is > > that too many write buffers take up more memory and longer to flush to > > disk. > > > > Minimum write buffers to merge: If most recently written keys are > > frequently changed, it is better to only flush the latest version to > > SSTable. This parameter controls how many Memtables it will try to merge > > before flushing to SSTable. It should be less than the write buffer > > number. A suggested value is 2. If the number is too big, it takes > > longer to merge buffers and there is less chance of duplicate keys in > > that many buffers. > > > > The list above is far from being exhaustive, but tuning them correctly > > can have a big impact on performance. Please refer to RocksDB’s Tuning > > Guide for more details on these parameters. Figuring out the optimal > > combination of values for all of them is an art in itself. > > > > please ref: https://klaviyo.tech/flinkperf-c7bd28acc67 > > > > regards. > > >