I have observed a loss of data when tservers fail during bulk ingest. The keys that are missing are right around the table's splits indicating that data was lost when a tserver died during a split. I am using Accumulo 1.5.0. At around the same time, I observe the master logging a message about "Found two locations for the same extent". Can anyone shed light on this behavior? Are tserver failures during bulk ingest supposed to be fault tolerant?
- data loss around splits when tserver goes down Anthony F
- Re: data loss around splits when tserver goes down Josh Elser
- Re: data loss around splits when tserver goes down Anthony F
- Re: data loss around splits when tserver goes dow... Anthony F
- Re: data loss around splits when tserver goes... Josh Elser
- Re: data loss around splits when tserver... Anthony F
- Re: data loss around splits when tse... Anthony F
- Re: data loss around splits when... Eric Newton
- Re: data loss around splits when... Anthony F
- Re: data loss around splits when... Eric Newton
- Re: data loss around splits when tserver goes dow... Josh Elser