Thanks! I will peruse the master logs. Is there a timeout that I can try
tinkering with to see if it might be a network issue?

Roshan

On Tue, Feb 3, 2015 at 10:43 AM, Josh Elser <[email protected]> wrote:

> The master will attempt to stop a TabletServer once it fails to get the
> status from that server 3 times (a simple RPC). You should see some more
> explanation WRT the actual Exceptions that lead to the Master requesting
> the stop from the TabletServer in the Master's log.
>
> During normal shutdown, the master will also ask TabletServers to stop,
> but I imagine that isn't the situation :)
>
>
> Roshan Punnoose wrote:
>
>> Hey all,
>>
>> Do you know why the Accumulo Master would request the TabletServer to
>> halt?
>>
>> On the tabletserver I just saw this exception:
>>
>> Master requested tablet server halt
>>
>>
>> Roshan
>>
>>