On Tue, Feb 12, 2019 at 7:38 PM Steve Niemitz <[email protected]> wrote: > > wow, thats super unexpected and dangerous, thanks for clarifying! Time to go re-think how we do some of our writes w/ early firings then. > > Are there any workarounds to make things happen in-order in dataflow? eg if the sink gets fused to the output of the GBK operation, will it always happen effectively in order (per key) even though it's not a guarantee?
If things get fused, yes. Note that sinks themselves sometimes have fusion barriers though. > I also guess I could keep track of the last pane index my sink has seen, and ignore earlier ones (using state to keep track)? Yes, that would work. What kind of sink are you using? If it supports read-modify-write or some kind of transaction you may be able to mark early results as tentative (which would be useful anyway) and only overwrite tentative ones. > On Tue, Feb 12, 2019 at 1:28 PM Robert Bradshaw <[email protected]> wrote: >> >> Correct, even within the same key there's no promise of event time ordering mapping of panes to real time ordering because the downstream operations may happen on a different machine. Multiply triggered windows add an element of non-determinism to the process. >> >> You're also correct that triggering with multiple panes requires lots of care, especially when it comes to operations with side effects (like sinks). Most safe is to only write the final pane to the sink, and handle early triggering in a different way. https://s.apache.org/beam-sink-triggers is a proposal to make this easier to reason about. >> >> >> On Tue, Feb 12, 2019 at 7:19 PM Steve Niemitz <[email protected]> wrote: >>> >>> Also to clarify here (I re-read this and realized it could be slightly unclear). My question is only about in-order delivery of panes. ie: will pane P always be delivered before P+1. >>> >>> I realize the use of "in-order" before could be confusing, I don't care about the ordering of the elements per-se, just the ordering of the pane delivery. >>> >>> I want to make sure that given a GBK that produces 3 panes (P0, P1, P2) for a key, a downstream PCollection could never see P0, P2, P1. OR at least, the final firing is always guaranteed to be delivered after all early-firings (eg we could have P0, P2, P1, but then always PLast). >>> >>> On Tue, Feb 12, 2019 at 11:48 AM Steve Niemitz <[email protected]> wrote: >>>> >>>> Are you also saying also that even in the first example (Source -> CombineByKey (Sum) -> Sink) there's no guarantee that events would be delivered in-order from the Combine -> Sink transforms? This seems like a pretty big "got-cha" for correctness if you ever use accumulating triggering. >>>> >>>> I'd also like to point out I'm not talking about a global ordering across the entire PCollection, I'm talking about within the same key after a GBK transform. >>>> >>>> On Tue, Feb 12, 2019 at 11:35 AM Robert Bradshaw <[email protected]> wrote: >>>>> >>>>> Due to the nature of distributed processing, order is not preserved. You can, however, inspect the PaneInfo to determine if an element was early, on-time, or late and act accordingly. >>>>> >>>>> On Tue, Feb 12, 2019 at 5:15 PM Juan Carlos Garcia < [email protected]> wrote: >>>>>> >>>>>> In my experience ordering is not guaranteed, you may need apply a transformation that sort the elements and then dispatch them sorted out. >>>>>> >>>>>> Or uses the Sorter extension for this: >>>>>> >>>>>> https://github.com/apache/beam/tree/master/sdks/java/extensions/sorter >>>>>> >>>>>> Steve Niemitz <[email protected]> schrieb am Di., 12. Feb. 2019, 16:31: >>>>>>> >>>>>>> Hi everyone, I have some questions I want to ask about how windowing, triggering, and panes work together, and how to ensure correctness throughout a pipeline. >>>>>>> >>>>>>> Lets assume I have a very simple streaming pipeline that looks like: >>>>>>> Source -> CombineByKey (Sum) -> Sink >>>>>>> >>>>>>> Given fixed windows of 1 hour, early firings every minute, and accumulating panes, this is pretty straight forward. However, this can get more complicated if we add steps after the CombineByKey, for instance (using the same windowing strategy): >>>>>>> >>>>>>> Say I want to buffer the results of the CombineByKey into batches of N elements. I can do this with the built-in GroupIntoBatches [1] transform, now my pipeline looks like: >>>>>>> >>>>>>> Source -> CombineByKey (Sum) -> GroupIntoBatches -> Sink >>>>>>> >>>>>>> This leads to my main question: >>>>>>> Is ordering preserved somehow here? ie: is it possible that the result from early firing F+1 now comes BEFORE the firing F (because it was re-ordered in the GroupIntoBatches). This would mean that the sink then gets F+1 before F, which means my resulting store has incorrect data (possibly forever if F+1 was the final firing). >>>>>>> >>>>>>> If ordering is not preserved, it seems as if I'd need to introduce my own ordering back in after GroupIntoBatches. GIB is an example here, but I imagine this could happen with any GBK type operation. >>>>>>> >>>>>>> Am I thinking about this the correct way? Thanks! >>>>>>> >>>>>>> [1] https://beam.apache.org/releases/javadoc/2.10.0/org/apache/beam/sdk/transforms/GroupIntoBatches.html >