If you are a WebLogic customer, you should open a support ticket: http://support.bea.com/application?namespace=case_management&origin=tool s_navbar.jsp&event=link.casemanagement
Click "Create a case". br -----Original Message----- From: Robert Read [mailto:[EMAIL PROTECTED] Sent: Tuesday, November 28, 2006 5:28 PM To: [email protected] Subject: Problem with Weblogic 9.2 console webapp Hi, I have been ding some configuration work for my Weblogic 9.2 server via its console. The console is a webapp that is created using Beehive PageFlows. I am now getting a 500 Internal Server Error and the following exception(s): <snip> ####<28/11/2006 03:39:14 PM NZDT> <Error> <Console> <ubuntu-GSX> <examplesServer> <[ACTIVE] ExecuteThread: '2' for queue: 'weblogic.kernel.Default (self-tuning)'> <weblogic> <> <> <1164681554143> <BEA-240003> <Console encountered the following error An error occurred parsing the default config file. The NetUI runtime is not properly configured.> ####<28/11/2006 03:39:14 PM NZDT> <Error> <Console> <ubuntu-GSX> <examplesServer> <[ACTIVE] ExecuteThread: '2' for queue: 'weblogic.kernel.Default (self-tuning)'> <weblogic> <> <> <1164681554152> <BEA-240003> <Console encountered the following error An error occurred parsing the default config file. The NetUI runtime is not properly configured.> ####<28/11/2006 03:39:15 PM NZDT> <Error> <Console> <ubuntu-GSX> <examplesServer> <[ACTIVE] ExecuteThread: '2' for queue: 'weblogic.kernel.Default (self-tuning)'> <weblogic> <> <> <1164681555731> <BEA-240003> <Console encountered the following error Page Flow Handlers not initialized; either org.apache.beehive.netui.pageflow.PageFlowActionServlet must be the Struts action servlet, or org.apache.beehive.netui.pageflow.PageFlowContextListener must be registered as a listener in web.xml.> ####<28/11/2006 03:39:15 PM NZDT> <Error> <Console> <ubuntu-GSX> <examplesServer> <[ACTIVE] ExecuteThread: '2' for queue: 'weblogic.kernel.Default (self-tuning)'> <weblogic> <> <> <1164681555760> <BEA-240003> <Console encountered the following error An error occurred parsing the default config file. The NetUI runtime is not properly configured.> ####<28/11/2006 03:39:15 PM NZDT> <Error> <HTTP> <ubuntu-GSX> <examplesServer> <[ACTIVE] ExecuteThread: '2' for queue: 'weblogic.kernel.Default (self-tuning)'> <<WLS Kernel>> <> <> <1164681555763> <BEA-101020> <[EMAIL PROTECTED] - appName: 'consoleapp', name: 'console', context-path: '/console'] Servlet failed with Exception java.lang.IllegalStateException: The NetUI runtime could not find the default config file. The webapp may not function properly. at org.apache.beehive.netui.util.config.ConfigUtil.getConfig(ConfigUtil.jav a:93) at org.apache.beehive.netui.pageflow.handler.Handlers.<init>(Handlers.java: 96) at org.apache.beehive.netui.pageflow.handler.Handlers.init(Handlers.java:84 ) at org.apache.beehive.netui.pageflow.handler.Handlers.get(Handlers.java:75) at org.apache.beehive.netui.pageflow.PageFlowUtils.getCurrentActionResolver (PageFlowUtils.java:301) at com.bea.portlet.adapter.scopedcontent.PageFlowStubImpl.initActionResolve r(PageFlowStubImpl.java:177) at com.bea.portlet.adapter.scopedcontent.ScopedContentCommonSupport.renderI nternal(ScopedContentCommonSupport.java:223) at com.bea.portlet.adapter.scopedcontent.PageFlowStubImpl.render(PageFlowSt ubImpl.java:136) at com.bea.netuix.servlets.controls.content.NetuiContent.preRender(NetuiCon tent.java:288) at com.bea.netuix.nf.ControlLifecycle$6.visit(ControlLifecycle.java:427) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:708) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walkRecursivePreRender(ControlTreeWa lker.java:720) at com.bea.netuix.nf.ControlTreeWalker.walk(ControlTreeWalker.java:183) at com.bea.netuix.nf.Lifecycle.processLifecycles(Lifecycle.java:361) at com.bea.netuix.nf.Lifecycle.processLifecycles(Lifecycle.java:339) at com.bea.netuix.nf.Lifecycle.runOutbound(Lifecycle.java:186) at com.bea.netuix.nf.Lifecycle.run(Lifecycle.java:146) at com.bea.netuix.servlets.manager.UIServlet.runLifecycle(UIServlet.java:37 0) > </snip> The key message appears to be: ####<28/11/2006 03:39:15 PM NZDT> <Error> <Console> <ubuntu-GSX> <examplesServer> <[ACTIVE] ExecuteThread: '2' for queue: 'weblogic.kernel.Default (self-tuning)'> <weblogic> <> <> <1164681555731> <BEA-240003> <Console encountered the following error Page Flow Handlers not initialized; either org.apache.beehive.netui.pageflow.PageFlowActionServlet must be the Struts action servlet, or org.apache.beehive.netui.pageflow.PageFlowContextListener must be registered as a listener in web.xml.> I guess the Page Flow Handlers may be what's missing from my web.xml file. Can anyone provide examples of these entries for me? Then I can compare with my web.xml and see what is missing. I am not familiar with either Struts or Beehive apart from the reading I have done in my attempts to solve this issue. >From reading the Beehive project pages I sort-of gather that the web.xml of a Beehive webapp gets generated during the build...I certainly can't find an example anywhere...but I am not sure that this is correct and nervous to try building Beehive in case I cause further issues (that I don't understand). If anyone can give me a pointer as to how to resurrect my Weblogic console that would be much appreciated. Kind regards, Robert Robert Read Analyst-Programmer ITS Group Applications The University of Auckland Telephone: +64 9 373 7599 ext 82475 Email: [EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> Web: http://www.auckland.ac.nz/ ________________________________ The information contained in this email message is intended only for the named recipient(s). If you are not the intended recipient(s), you must not peruse, use, disseminate, distribute or copy this email or attachments. If you receive this email in error please immediately notify the sender and delete the original message. _______________________________________________________________________ Notice: This email message, together with any attachments, may contain information of BEA Systems, Inc., its subsidiaries and affiliated entities, that may be confidential, proprietary, copyrighted and/or legally privileged, and is intended solely for the use of the individual or entity named in this message. If you are not the intended recipient, and have received this message in error, please immediately return this by email and then delete it.