1/ using SSD : trickle_fsync: true trickle_fsync_interval_in_kb: 1024 2/ concurrent_compactors to the number of cores. 3/ concurrent_counter_writes 4/ Row Cache vs Chunk Cache5/ change the compaction method to leveled, specifically when using counter columns ??
thanks !
On 3 September 2017 at 20:25, Rudi Bruchez <r...@babaluga.com <mailto:r...@babaluga.com>> wrote:Le 30/08/2017 à 05:33, Erick Ramirez a écrit :Is it possible at all that you may have a data hotspot if it's not hardware-related?It does not seem so, The partition key seems well distributed and the queries update different keys. We have dropped counter_mutation messages in the log : COUNTER_MUTATION messages were dropped in last 5000 ms: 0 internal and 2 cross node. Mean internal dropped latency: 0 ms and Mean cross-node dropped latency: 5960 msPool Name Active Pending Completed Blocked All Time BlockedReadStage 32 503 7481787 0 0CounterMutationStage 32 221 5722101 0 0The load could be too high ? Thanks
<<attachment: rudi.vcf>>
smime.p7s