We're using Oracle and sequences, not an AUTO_PK table to generate the keys.
I've added logging into the custom code that pulls sequences, and the values
are right at that point. But when I look at the code that calls that, I find
right after the call:
if (pk.getType() == Types.BIGINT) {
return Long.valueOf(value);
}
else {
// leaving it up to the user to ensure that PK does not exceed max
int...
return Integer.valueOf((int) value);
}
How do I specify a primary key type to be BIGINT? Would anything break if I
changed my copy of this code to always return a Long instead of an Integer?
Joe
On Jul 19, 2012, at 5:15 PM, Aristedes Maniatis wrote:
> Look at the columns widths of the AUTO_PK table?
>
> Ari
>
> On 20/07/12 10:07am, Joseph Senecal wrote:
>> We are using Cayenne 3.1 M3 in production. We have just discovered that the
>> primary keys being generated are being truncated to fit an int.
>>
>> The sequence returns numbers like 5224748590. I've confirmed this by logging
>> the return value of LongPkRange.getNextPrimaryKey.
>>
>> But the inserts are using PKs like 929781294. 5224748590 - 2^32 = 929781294.
>> Something is stripping off the high order bits of the primary keys.
>>
>> I've checked my model, there the primary key is Defined as Number(15) in the
>> database, but it isn't defined as an attribute at all, so I can't specify
>> the Java class to use for it.
>>
>> Anyone have any suggestions?
>>
>
> --
> -------------------------->
> Aristedes Maniatis
> GPG fingerprint CBFB 84B4 738D 4E87 5E5C 5EFA EF6A 7D2E 3E49 102A