Yup! Thanks.

Moiz

—
sent from phone

On 19-Jul-2017, at 9:21 PM, Aljoscha Krettek [via Apache Flink User Mailing 
List archive.] <ml+s2336050n14337...@n4.nabble.com> wrote:

This was now answered in your other Thread, right?

Best,
Aljoscha

>> On 18. Jul 2017, at 11:37, Moiz Jinia <[hidden email]> wrote:
>> 
>> Aljoscha Krettek wrote
>> Hi,
>> zero-downtime updates are currently not supported. What is supported in
>> Flink right now is a savepoint-shutdown-restore cycle. With this, you
>> first
>> draw a savepoint (which is essentially a checkpoint with some meta data),
>> then you cancel your job, then you do whatever you need to do (update
>> machines, update Flink, update Job) and restore from the savepoint.
>> 
>> A possible solution for zero-downtime update would be to do a savepoint,
>> then start a second Flink job from that savepoint, then shutdown the first
>> job. With this, your data sinks would need to be able to handle being
>> written to by 2 jobs at the same time, i.e. writes should probably be
>> idempotent.
>> 
>> This is the link to the savepoint doc:
>> https://ci.apache.org/projects/flink/flink-docs-release-1.2/setup/savepoints.html
>> 
>> Does that help?
>> 
>> Cheers,
>> Aljoscha
>> 
>> On Fri, 16 Dec 2016 at 18:16 Andrew Hoblitzell &lt;
> 
>> ahoblitzell@
> 
>> &gt;
>> wrote:
>> 
>>> Hi. Does Apache Flink currently have support for zero down time or the =
>>> ability to do rolling upgrades?
>>> 
>>> If so, what are concerns to watch for and what best practices might =
>>> exist? Are there version management and data inconsistency issues to =
>>> watch for?=
>>> 
> 
> When a second job instance is started in parallel from a savepoint, my
> incoming kafka messages would get sharded between the 2 running instances of
> the job (since they both would belong to the same consumer group). So when I
> stop the older version of the job, i stand to lose data (inspite of the fact
> that my downstream consumer is idempotent)
> 
> If I used a different consumer group for the new job version (and start it
> from a savepoint), will the savepoint ensure that the second job instance
> starts from the correct offset? Do I need to do anything extra to make this
> work? (example set the uid on the source of the job).
> 
> Thanks!
> Moiz
> 
> 
> 
> --
> View this message in context: 
> http://apache-flink-user-mailing-list-archive.2336050.n4.nabble.com/Flink-rolling-upgrade-support-tp10674p14313.html
> Sent from the Apache Flink User Mailing List archive. mailing list archive at 
> Nabble.com.



If you reply to this email, your message will be added to the discussion below:
http://apache-flink-user-mailing-list-archive.2336050.n4.nabble.com/Flink-rolling-upgrade-support-tp10674p14337.html