Hi all,

In FLINK-26444, a couple of convenience window assigners were added to the Python Datastream API, including CountTumblingWindowAssigner. This assigner uses a CountTrigger by default, which produces TriggerResult.FIRE.

As such, using this window assigner on a data stream will always produce a "state leak" since older count windows will always be retained without any chance to work on the elements again.

Unless I am mistaken, the only way to use this assigner would be to override its trigger with .trigger() afterwards? In this case, should the default trigger for this assigner not be one with a TriggerResult.FIRE_AND_PURGE?

Would be happy to file a bug and/or produce a PR for this but wanted to check with the list first to make sure I'm not missing anything here.

Thanks,
Urs

--