Am 07.04.21 um 17:10 schrieb Tom Lawson:
Does it connect if you wait longer?
It's a bit more complicated. The machines are in a "balancing connection group", so that each user only can have one connection at the same time.
Yes, it does work if "enable session affinity" is activated. And No if this option is disabled. Then it is looping. Reconnecting after 15 seconds (countdown) then connection timeout after 15 seconds. And so on, even if the machine is running meanwhile.
If I deleting "wol-wait-time" completely login works immediatly if the machine is already running. If not, after one or two "connection errors" it does connect.
But for the normal users the "connection error" can be irritating. I would await, that if "wol-wait-time" is configured, that no error is shown at least.
Regards Thomas -- Karlsruher Institut für Technologie (KIT) archIT [IT-Management der Fakultät Architektur] Dipl.-Ing. Thomas Besser Gebäude 11.40, Raum 010 | Fon +49 721 608 46024 http://www.arch.kit.edu/fakultaet/it-management.php KIT - Die Forschungsuniversität in der Helmholtz-Gemeinschaft