That worked.  Thank you very much.

Would you please elaborate on how property is used?
Does it imply that by default autoflushFrequency is disabled and
DataStreamer will NOT
write data to cache unless explicitly set?

I basically modeled my JMSStreamer after the following documentation here:
https://apacheignite.readme.io/docs/jms-data-streamer
The docs do not explicitly mention setting 'autoflushFrequency'..


Here is definition from Apache Ignite docs: -
dataStreamer.autoFlushFrequency:


"Sets automatic flush frequency. Essentially, this is the time after which
the streamer will make an attempt to submit all data added so far to remote
nodes. Note that there is no guarantee that data will be delivered after
this concrete attempt (e.g., it can fail when topology is changing), but it
won't be lost anyway.

If set to 0, automatic flush is disabled.

Automatic flush is disabled by default (default value is 0)."


Please advise.

Thank you






--
View this message in context: 
http://apache-ignite-users.70518.x6.nabble.com/JMS-Data-Streamer-Not-writing-data-to-cache-when-message-received-by-Streamer-tp3590p3592.html
Sent from the Apache Ignite Users mailing list archive at Nabble.com.

Reply via email to