Please provide full thread dumps from all the nodes at the time it happens 
again.
In particular I’m interested in what is going with the thread named 
"ipc-shmem-gc”. In addition to the thread dumps attache the logs from all the 
nodes for investigation.

As a workaround you can disable shmem as it was suggested before. Finally I 
would recommend upgrading to the latest Ignite 1.6.0 version.

—
Denis

> On Jun 24, 2016, at 3:30 PM, bintisepaha <[email protected]> wrote:
> 
> JDK 1.7, 16 node cluster, each JVM 10 GB heap and 4 GB off heap. 4 nodes run
> on 4 linux boxes, each box has 64 GB memory. the heap is under-utilized when
> this happens. so doubt GC will cause it.
> multiple clients connect to it. clients cannot exit properly either with
> System.exit() or Ignition.stop().
> 
> We did not have the issue on our end until this week, but then something
> could have changed with ports in our environment. We cannot reproduce
> ourselves in UAT it only happens for us in Production.
> 
> 
> 
> 
> 
> --
> View this message in context: 
> http://apache-ignite-users.70518.x6.nabble.com/System-exit-not-exiting-cleanly-locked-on-IgnitionEx-IgniteNamedInstance-tp5814p5876.html
> Sent from the Apache Ignite Users mailing list archive at Nabble.com.

Reply via email to