Thanks Dmitry! On Fri, Sep 8, 2017 at 4:57 AM, Dmitry Pavlov <[email protected]> wrote:
> Hi John, > > > > Quite long page will require Ignite to use much time during loading page > from disk or write it back during checkpointing. Ignite is able to change > field value pointwise within page in case of update. In that case and if > too long page is selected, one field update, for example 1 byte will > require ignite to checkpoint 16K+ of data at next checkpoint. > > > > Going deeply to techical details: 16 K limitation came from internal > 2-byte addressing of data within page. There is internal offset named > 'item' which is 2 bytes in length and has 2 bits flags in it. 2^14=16384 > > > > Sincerely, > > Dmitriy Pavlov > > > пт, 8 сент. 2017 г. в 0:22, John Wilson <[email protected]>: > >> Hi, >> >> Ignite sets the maximum possible size for a page to 16KB. Why? What are >> the drawbacks of having bigger page sizes? >> >> https://github.com/apache/ignite/blob/bd7bd226d959fbc686f6104a048106 >> b7b944347b/modules/core/src/main/java/org/apache/ignite/configuration/ >> MemoryConfiguration.java#L179 >> >> Thanks, >> >