Thanks for clarify! Regards Aaron From: Loredana Radulescu Ivanoff Date: 2018-12-21 02:40 To: user Subject: Re: Re: Partition-exchanger blocked after upgrade to 2.7 Hello,
We've been witnessing a similar set of logs from Apache Ignite after upgrading to 2.7 (from 2.6) in a couple of different environments, one of which had only one Ignite node. Very frequently, ignite will log the message "Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour [threadName=partition-exchanger, blockedFor=13s]" and write a full thread dump. An examination of the thread dump does not seem to indicate any specific threads that are actually blocked or delayed. We do not appear to have any cluster wide issues despite the logging. In our understanding the sysWorkerBlockedTimeout property defaults to DFLT_FAILURE_DETECTION_TIMEOUT. We have the failure detection timeout configured to 10s. We do not have a solution for it so far. On Thu, Dec 20, 2018 at 7:34 AM ilya.kasnacheev <[email protected]> wrote: Hello! Do you have any non-standard settings for failureDetectionTimeout or networkTimeout? Do you have any observable issues besides occasional extra logging? Regards, -- Sent from: http://apache-ignite-users.70518.x6.nabble.com/