Hello!

It is a known regression in 2.7:
http://apache-ignite-developers.2346864.n4.nabble.com/System-Worker-Failure-Handler-on-local-laptop-tp39810p39812.html
"To workaround the issue, you should set
DataStorageConfiguration#setCheckpointReadLockTimeout
to 0."

Increasing failureDetectionTimeout also helps.

Regards,
-- 
Ilya Kasnacheev


чт, 10 янв. 2019 г. в 18:47, yangjiajun <[email protected]>:

> Hello.
>
> I have a ignite 2.7 node with persistence enabled.I use it as a database.It
> reported "blocked system-critical thread has been detected" exception in
> logs.I guess it was blocked by drop table operations.Can someone help me to
> find what happened to ignite?
>
> Here is the logs and config of ignite:
> ignite-b2c59b25.rar
> <
> http://apache-ignite-users.70518.x6.nabble.com/file/t2059/ignite-b2c59b25.rar>
>
> ignite-b2c59b25.rar
> <
> http://apache-ignite-users.70518.x6.nabble.com/file/t2059/ignite-b2c59b25.rar>
>
> example-default1.xml
> <
> http://apache-ignite-users.70518.x6.nabble.com/file/t2059/example-default1.xml>
>
>
> I delete some logs because my company has upload file size limit.I will try
> to upload it on another post.
>
>
>
> --
> Sent from: http://apache-ignite-users.70518.x6.nabble.com/
>