Hi,

Just Ignition.stop(true);  should be enough to wait till checkpoint ends.
So it could be just one call to this method without anything else.

If you did a prior call to ignite.close() this is equal to
Ignition.stop(false) and this cause Ignite node to stop without waiting for
checkpoint to finish. In that case, further calls have no effect.

In any case, this warning says that it may require a longer time to restore
memory during start-up, but not something that is dangerous for data.

Sincerely,
Dmitriy Pavlov

вт, 23 апр. 2019 г. в 22:58, Jorg Janke <[email protected]>:

> We try to shut down Ignite properly via:
>
>     m_ignite.close(); // Ignite.close()
>     m_ignite.executorService().shutdown();
>     Ignition.stop(true);
>
> but still get:
>
> WARN: Ignite node stopped in the middle of checkpoint. Will restore memory
> state and finish checkpoint on node start.
>
> What is the recommended way to stop/shut down an (embedded) ignite
> instance?
>
> Thanks!
> Jorg
>
> Jorg Janke - www.accorto.com - (650) 227-3271
>