Hi Igniters,
We have three server nodes, there is firewall between clients and servers.
Opened 47500 and 47100 series ports, but still below errors are printing at
client side frequently. But client application able to get data from cluster,
could please help us how to avoid these errors at client side.
We are using Ignite 2.7.0 version.
[2020-10-08T00:26:23,389][ERROR][grid-nio-worker-tcp-comm-0-#24%JBPLCustomer%][TcpCommunicationSpi]
Failed to process selector key [ses=GridSelectorNioSessionImpl
[worker=DirectNioClientWorker [super=AbstractNioClientWorker [idx=0,
bytesRcvd=84608, bytesSent=1725593, bytesRcvd0=0, bytesSent0=0, select=true,
super=GridWorker [name=grid-nio-worker-tcp-comm-0,
igniteInstanceName=JBPLCustomer, finished=false, heartbeatTs=1602096980980,
hashCode=1228592538, interrupted=false,
runner=grid-nio-worker-tcp-comm-0-#24%JBPLCustomer%]]],
writeBuf=java.nio.DirectByteBuffer[pos=0 lim=32768 cap=32768],
readBuf=java.nio.DirectByteBuffer[pos=0 lim=32768 cap=32768],
inRecovery=GridNioRecoveryDescriptor [acked=48, resendCnt=0, rcvCnt=58,
sentCnt=48, reserved=true, lastAck=58, nodeLeft=false, node=TcpDiscoveryNode
[id=ef6723ee-f70d-4515-89b9-7a3e85ab5072, addrs=[0:0:0:0:0:0:0:1%lo, clientIP,
127.0.0.1, 2405:200:a60:fd04:20c:29ff:fe63:629f%eth0], sockAddrs=[/clientIP:0,
0:0:0:0:0:0:0:1%lo:0, /127.0.0.1:0,
2405:200:a60:fd04:20c:29ff:fe63:629f%eth0:0], discPort=0, order=72,
intOrder=64, lastExchangeTime=1602089183465, loc=false,
ver=2.7.0#20181201-sha1:256ae401, isClient=true], connected=true, connectCnt=0,
queueLimit=4096, reserveCnt=1, pairedConnections=false],
outRecovery=GridNioRecoveryDescriptor [acked=48, resendCnt=0, rcvCnt=58,
sentCnt=48, reserved=true, lastAck=58, nodeLeft=false, node=TcpDiscoveryNode
[id=ef6723ee-f70d-4515-89b9-7a3e85ab5072, addrs=[0:0:0:0:0:0:0:1%lo, clientIP,
127.0.0.1, 2405:200:a60:fd04:20c:29ff:fe63:629f%eth0], sockAddrs=[/clientIP:0,
0:0:0:0:0:0:0:1%lo:0, /127.0.0.1:0,
2405:200:a60:fd04:20c:29ff:fe63:629f%eth0:0], discPort=0, order=72,
intOrder=64, lastExchangeTime=1602089183465, loc=false,
ver=2.7.0#20181201-sha1:256ae401, isClient=true], connected=true, connectCnt=0,
queueLimit=4096, reserveCnt=1, pairedConnections=false],
super=GridNioSessionImpl [locAddr=/Server1IP:47100, rmtAddr=/clientIP:52303,
createTime=1602089184427, closeTime=0, bytesSent=248963, bytesRcvd=1559,
bytesSent0=0, bytesRcvd0=0, sndSchedTime=1602096401587,
lastSndTime=1602089666831, lastRcvTime=1602096401587, readsPaused=false,
filterChain=FilterChain[filters=[GridNioCodecFilter
[parser=o.a.i.i.util.nio.GridDirectParser@18323d50, directMode=true],
GridConnectionBytesVerifyFilter], accepted=true, markedForClose=false]]]
java.io.IOException: Connection reset by peer
at sun.nio.ch.FileDispatcherImpl.read0(Native Method)
~[?:1.8.0_151]
at sun.nio.ch.SocketDispatcher.read(SocketDispatcher.java:39)
~[?:1.8.0_151]
at sun.nio.ch.IOUtil.readIntoNativeBuffer(IOUtil.java:223)
~[?:1.8.0_151]
at sun.nio.ch.IOUtil.read(IOUtil.java:192) ~[?:1.8.0_151]
at
sun.nio.ch.SocketChannelImpl.read(SocketChannelImpl.java:380) ~[?:1.8.0_151]
at
org.apache.ignite.internal.util.nio.GridNioServer$DirectNioClientWorker.processRead(GridNioServer.java:1275)
~[ignite-core-2.7.0.jar:2.7.0]
at
org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.processSelectedKeysOptimized(GridNioServer.java:2389)
[ignite-core-2.7.0.jar:2.7.0]
at
org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.bodyInternal(GridNioServer.java:2156)
[ignite-core-2.7.0.jar:2.7.0]
at
org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.body(GridNioServer.java:1797)
[ignite-core-2.7.0.jar:2.7.0]
at
org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120)
[ignite-core-2.7.0.jar:2.7.0]
at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]
Thanks and Regards,
Kamlesh Joshi
"Confidentiality Warning: This message and any attachments are intended only
for the use of the intended recipient(s).
are confidential and may be privileged. If you are not the intended recipient.
you are hereby notified that any
review. re-transmission. conversion to hard copy. copying. circulation or other
use of this message and any attachments is
strictly prohibited. If you are not the intended recipient. please notify the
sender immediately by return email.
and delete this message and any attachments from your system.
Virus Warning: Although the company has taken reasonable precautions to ensure
no viruses are present in this email.
The company cannot accept responsibility for any loss or damage arising from
the use of this email or attachment."