Hi Chris,
I am also experimenting with CC. For me chosing CosineDistanceMeasure
and values very close to 1 (>0.96) with T2 being only a little smaller
than T1 led to reasonable values for k. Although this puzzles me too, I
just asked a another question because of this.
-----Ursprüngliche Mitteilung-----
Von: Chris Harrington <[email protected]>
An: user <[email protected]>
Verschickt: Do, 31 Jan 2013 7:22 pm
Betreff: Figuring out good values for t1 and t2 for canopy
Hi all,
I'm trying to run canopy clustering before means and I can't seem to
get a value
for t1 and t2 that give me any results.
No matter what values I use it results in no clusters.
This is probably due to a severe lack of knowledge on the subject on my
part so
can anyone point me toward some good resources to read up on the topic
of
choosing a distance measure and a t1 and t2 for that measure?