If going to app_confbridge then make sure to always use the latest stable releases of Asterisk. Confbridge underwent a major rewrite/overhaul for Asterisk 10.0 and has since had many additional fixes. Also, meetme has options that help conserve bandwidth such as talk detection; where audio (silence or background noise) from non-talking users isn't mixed in the audio bridge (there's a silence threshold to configure this). Meeme has options to auto drop a bridge once last user leaves.
For a comparison/note from the devs about differences when Confbridge was overhauled https://wiki.asterisk.org/wiki/display/AST/ConfBridge+10 For latest Meetme info see https://wiki.asterisk.org/wiki/display/AST/Asterisk+11+Application_MeetMe For latest Confbridge info see https://wiki.asterisk.org/wiki/display/AST/Asterisk+11+Application_ConfBridge -----Original Message----- From: Maxim Solodovnik [mailto:[email protected]] Sent: Thursday, February 28, 2013 9:02 AM To: Openmeetings user-list; dev Subject: [ANNOUNCE] SIP in Openmeetings is changed Hello All, I would like to announce major changes in SIP in upcoming 2.1 release 1. Confbridge is used instead of MeetMe. 2. OM video codec is changed to be H264 3. Calls to OM rooms will not start until there is no OM users in the room, and will automatically ends as soon as last user will leave the room. All changes above were made to enable SIP video conferences and increase SIP integration stability. (currently in progress) Intergation instruction is up to date and available here: http://openmeetings.apache.org/red5sip-integration_2.1.html The only known issue at the moment is: red5sip will not reconnect to OM after OM was restarted (going to fix) I would like to get feedback regarding SIP integration: documentation, issues, improvements etc. before release. Thanks in advance -- WBR Maxim aka solomax ________________________________ DISCLAIMER: This email may contain confidential information and is intended only for the use of the specific individual(s) to which it is addressed. If you are not the intended recipient of this email, you are hereby notified that any unauthorized use, dissemination or copying of this email or the information contained in it or attached to it is strictly prohibited. If you received this message in error, please immediately notify the sender at Infotech and delete the original message.