Hi, the main difference between CAS consumers and analysis engines is that the former be default run only a single instance and the latter can be multiplied. If your consumer code can be run in parallel, just try inheriting from AnalysisEngine_ImplBase (or something like that) instead.
Cheers, -- Richard Am 10.10.2012 um 12:00 schrieb Timo Boehme <[email protected]> : > Hi, > > is there any possibility without using UIMA-AS to run different CAS consumer > components of a pipeline in parallel? > The standard behavior is that the consumer are called in sequence, but since > in my case they don't depend on each other it would be more efficient to have > them run in parallel. Can I use CAS multiplier + Flow control to achieve this? > > > Thanks, > Timo > > -- > > Timo Boehme > OntoChem GmbH > H.-Damerow-Str. 4 > 06120 Halle/Saale > T: +49 345 4780474 > F: +49 345 4780471 > [email protected] -- ------------------------------------------------------------------- Richard Eckart de Castilho Technical Lead Ubiquitous Knowledge Processing Lab (UKP-TUD) FB 20 Computer Science Department Technische Universität Darmstadt Hochschulstr. 10, D-64289 Darmstadt, Germany phone [+49] (0)6151 16-7477, fax -5455, room S2/02/B117 [email protected] www.ukp.tu-darmstadt.de Web Research at TU Darmstadt (WeRC) www.werc.tu-darmstadt.de -------------------------------------------------------------------