Hi,

the main difference between CAS consumers and analysis engines is that the 
former be default run only a single instance and the latter can be multiplied. 
If your consumer code can be run in parallel, just try inheriting from 
AnalysisEngine_ImplBase (or something like that) instead.

Cheers,

-- Richard

Am 10.10.2012 um 12:00 schrieb Timo Boehme <[email protected]>
:

> Hi,
> 
> is there any possibility without using UIMA-AS to run different CAS consumer 
> components of a pipeline in parallel?
> The standard behavior is that the consumer are called in sequence, but since 
> in my case they don't depend on each other it would be more efficient to have 
> them run in parallel. Can I use CAS multiplier + Flow control to achieve this?
> 
> 
> Thanks,
> Timo
> 
> -- 
> 
> Timo Boehme
> OntoChem GmbH
> H.-Damerow-Str. 4
> 06120 Halle/Saale
> T: +49 345 4780474
> F: +49 345 4780471
> [email protected]


-- 
------------------------------------------------------------------- 
Richard Eckart de Castilho
Technical Lead
Ubiquitous Knowledge Processing Lab (UKP-TUD) 
FB 20 Computer Science Department      
Technische Universität Darmstadt 
Hochschulstr. 10, D-64289 Darmstadt, Germany 
phone [+49] (0)6151 16-7477, fax -5455, room S2/02/B117
[email protected] 
www.ukp.tu-darmstadt.de 
Web Research at TU Darmstadt (WeRC) www.werc.tu-darmstadt.de
------------------------------------------------------------------- 