That is really odd. None of the xfire classes hardcode the woodstox refence. Maybe it is in a parent classpath or something??

Also, why are you using the RI? It is awful, slow and buggy. You really should use Woodstox :-)

- Dan

Adam Kramer wrote:
I have a deployed web service that whenever it attempts to generate WSDL, generates and error that it is looking for the Woodstox implementation of stax.

WSTX is not on the classpath, but the RI stax-dev-1.1.2 is. Below is the stacktrace: javax.xml.stream.FactoryConfigurationError: Provider com.ctc.wstx.stax.WstxInputFactory not found
   at javax.xml.stream.FactoryFinder.newInstance(FactoryFinder.java:72)
   at javax.xml.stream.FactoryFinder.find(FactoryFinder.java:120)
   at javax.xml.stream.FactoryFinder.find(FactoryFinder.java:92)
at javax.xml.stream.XMLInputFactory.newInstance(XMLInputFactory.java:136)
   at org.codehaus.xfire.util.STAXUtils.<clinit>(STAXUtils.java:47)
at org.codehaus.xfire.util.jdom.StaxBuilder.<init>(StaxBuilder.java:150) at org.codehaus.xfire.wsdl11.builder.AbstractWSDL.<clinit>(AbstractWSDL.java:50) at org.codehaus.xfire.wsdl11.builder.DefaultWSDLBuilderFactory.createWSDLBuilder(DefaultWSDLBuilderFactory.java:25)
.
.
.

Any idea why it won't find the BEA stax impl?

Adam


--
Dan Diephouse
Envoi Solutions
http://envoisolutions.com
http://netzooid.com/blog